| Lieu d'origine: | Chine |
|---|---|
| Nom de marque: | Advanced Instruments |
| Certification: | ASTM D943 |
| Numéro de modèle: | AIC-943 |
| Quantité de commande min: | 1 ensemble |
| Prix: | US$5000-10,000/set |
| Détails d'emballage: | Caisse en contreplaqué |
| Délai de livraison: | 30 jours |
| Conditions de paiement: | T / T, L / C, D / P |
| Capacité d'approvisionnement: | 50sets par mois |
| norme d'essai: | ASTM D943 | Garantie: | 1 année complète |
|---|---|---|---|
| Trandmark: | Instruments avancés | Alimentation: | AC220V 50Hz |
| Service OEM: | Disponible | Méthode de chauffage: | tige de chauffage électrique |
| Mode de contrôle de la température: | contrôleur de température importé de PID | Précision de contrôle de la température: | Ambiante ~ 200 ± 0,1 ℃ |
| Unités de fonctionnement: | 6 unités | Contrôle de flux: | compteur de débit de précision |
| Puissance totale: | Environ 2,5 kW | Plage de débit: | 0 ~ 200 ml/h |
| Mettre en évidence: | Oxidation stability tester ASTM D943,Mineral oil oxidation tester,Oil test equipment with warranty |
||
This Inhibited Mineral Oil Oxidation Stability Tester is suitable for determining the oxidative stability of unused mineral insulating oils with inhibitors, and can also be used for the tendency of unused mineral insulating oils to form acids and precipitates before and after the induction period. Mechanism: The sample was kept at 120°C in the presence of the copper catalyst coil, while a constant flow of oxygen was passed through, and the time required for the volatile acid generated by the oxidation of the sample to increase to a neutralization value equivalent to 0.28 gKOH/g was measured. The oxidative stability of the sample is represented by the induction period (h).
|
Applicable standards
|
ASTM D943
|
|
Heating mode
|
Electric heating rod
|
|
Temperature Control Mode
|
Imported digital display PID temperature controller
|
|
Temperature Control Accuracy
|
±0.1℃
|
|
Temperature Control Range
|
Ambient temperature ~ 120℃
|
|
Working units
|
6 Units
|
|
Timing Mode
|
Digital display timer
|
|
Flow Range
|
0 ~ 200 mL/h
|
|
Flow Control
|
Precision flow meter
|
|
Total Power
|
About 2.5KW
|
|
Dimension
|
630mm*710mm*930mm
|
|
Net Weight
|
50 kg
|
|
Power supply
|
AC 220V ,50Hz
|